Troubleshooting

Start with the stage that failed. Read its logs, then check the relevant configuration and dependencies.

Symptom Start here
Installation or initialization fails Installation and configuration issues below
Service works but cache is not reused External-cache verification
Storage operations are blocked Storage health
Only an error code is available Error code reference

Common Issues

Installation & Build Issues

PLATFORM environment variable not set

Log message:

WARNING: PLATFORM environment variable is not set!
Please set PLATFORM to one of: cuda, ascend, ascend-a3, musa, maca

Cause: The PLATFORM env var is required for building UCM. Without it, the build defaults to simu (simulation mode) which is only for CI testing.

Solution:

export PLATFORM=cuda       # For CUDA
export PLATFORM=ascend     # For Ascend A2
export PLATFORM=ascend-a3  # For Ascend A3
pip install -v -e . --no-build-isolation

Build fails with CMake errors

Cause: Missing build dependencies (cmake, gcc, or CUDA toolkit not in path).

Solution: 1. Ensure cmake >= 3.18 is installed: cmake --version 2. Ensure the CUDA toolkit is installed and nvcc is accessible: nvcc --version 3. For Ascend, ensure the CANN toolkit is properly installed

pip install fails with wheel build errors

Cause: Building C++ extensions requires a proper compiler environment. On some systems, --no-build-isolation may fail if the build toolchain is not set up.

Solution: Select a published runtime image or a Wheel with its backend extra from Installation.


Configuration Issues

Error Code -50000 (InvalidParam)

Typical log:

invalid param ... InvalidParam(...)

Common causes: - YAML configuration file has syntax errors - Required parameter is missing - Parameter value type is wrong (e.g. string where integer is expected)

Solution: 1. Check YAML syntax: validate with python -c "import yaml; yaml.safe_load(open('your_config.yaml'))" 2. Verify parameter names match the Pipeline Store documentation 3. Ensure storage_backends path is a valid string, not empty

UCM_CONFIG_FILE not found

Log message:

UCM config file not found: <path>

Cause: The config file path in kv_connector_extra_config is incorrect or the file does not exist.

Solution: Verify the file path exists and is accessible from the container or process. In Docker, ensure the file is mounted or copied into the container.

Unsupported connector type

Log message:

Unsupported connector type: <name>

Cause: The ucm_connector_name in the config is not a registered connector.

Solution: Use the supported connector name: UcmPipelineStore.

Unknown store pipeline

Log message:

unknown store pipeline: <name>

Cause: The store_pipeline value is not registered in the PipelineStore registry.

Solution: Use a registered pipeline such as "Cache|Posix", "Cache|Ds3fs", "Cache|Compress|Posix", etc. See ucm/store/pipeline/connector.py for all registered pipelines.


Runtime Issues

Error Code -50001 (OutOfMemory)

Common causes: - cache_buffer_capacity_gb is set too large for available /dev/shm - Multiple DP instances on the same node each allocate their own CacheStore buffer - MLA models require more shared memory

Solution: 1. Check system memory: free -h 2. Check shared memory: df -h /dev/shm 3. Set a positive explicit cache_buffer_capacity_gb appropriate to the host. Without one, native Cache Store uses 256 GiB with shared buffers or 32 GiB per unshared worker; the vLLM shared-buffer path supplies 128 GiB. Account for every unshared worker on the host. 4. When running multiple DP instances on one node, reduce the value proportionally

Error Code -50002 (OsApiError)

Common causes: - The storage_backends directory does not exist - Permission denied on the storage directory - Disk I/O error or filesystem issue

Solution: 1. Verify the path exists: ls <storage_backends_path> 2. Check write permissions: touch <storage_backends_path>/test_file && rm <storage_backends_path>/test_file 3. For NFS mounts, verify the mount is healthy: mount | grep <path> 4. Check system logs: dmesg | tail or journalctl -xe

Error Code -50009 (NoSpace)

Common causes: - Disk space is full at the storage_backends path - posix_capacity_gb is set larger than actual disk capacity - GC is not enabled or not aggressive enough

Solution: 1. Check disk space: df -h <storage_backends_path> 2. Set posix_capacity_gb within the capacity budget available to this deployment; leave space for other users of the filesystem. 3. GC is automatically enabled when posix_capacity_gb > 0 — verify it is set correctly

Error Code -50010 (Timeout)

Common causes: - Network or storage bandwidth is abnormal (e.g. NFS mount degraded) - System load is too high (CPU, I/O saturation) - timeout_ms is set too low for the workload

Solution: 1. Inspect storage latency, I/O errors, and UCM task timings. If a benchmark is needed, use a dedicated test directory and an approved storage workload. 2. Check system load: top or htop 3. Check network: ping and iperf for NFS over network 4. Set timeout_ms inside ucm_connector_config if a measured operation needs a larger timeout (default 30000 ms); a YAML-root key does not configure Store I/O. 5. For NFS, check the client/server logs and mount options against the storage deployment requirements before changing cache or consistency settings.


vLLM Integration Issues

Prefix Caching not working (no cache hits)

Log message:

request_id: xxx, total_blocks_num: N, hit hbm: 0, hit external: 0

Cause: A first request has no reusable external blocks. Later requests require successful writes, matching token prefixes/model identity, enough full blocks, and the same cache geometry.

Solution: 1. Verify the UCM_CONFIG_FILE path and effective Store configuration in the startup log. 2. Check completed writes and replay an identical multi-block prompt after restarting the engine while preserving storage. See the external-cache check. 3. Inspect UCM hit tokens and load activity separately from native HBM cache hits; native prefix caching and external UCM reuse are distinct paths.

Unsupported device platform for UCMDirectConnector

Cause: The current platform is neither CUDA nor Ascend NPU.

Solution: This error describes the selected vLLM direct-connector path. Match the connector and engine to the actual device; it is not a statement that every UCM component supports only these two platforms. Check the Support Matrix and the selected build.

KV dump/load errors

Typical logs:

dump kv cache failed. <error>
wait for dump kv cache failed. <error>
submit dump task failed. <error>

Cause: Store backend (Posix/NFS) encountered I/O errors during KV cache transfer.

Solution: 1. Check storage backend health (disk space, permissions, network) 2. Set UC_LOGGER_LEVEL=debug for detailed transfer logs:

[UC][D] Cache task(...) dispatching.
[UC][D] Posix task(...) dispatching.
3. Check if the error code matches one from the error code reference


Log Debugging

To view detailed UCM transfer logs, set the environment variable:

export UC_LOGGER_LEVEL=debug

This produces per-task logs with task IDs, operation types, data sizes, and timing:

[UC][D] Cache task({task_id},{operation},{subtask_number},{size}) dispatching. [PID,TID]
[UC][D] Cache task({task_id},{operation},{subtask_number},{size}) finished, cost {time}ms. [PID,TID]
[UC][D] Posix task({task_id},{operation},{subtask_number},{size}) dispatching. [PID,TID]
[UC][D] Posix task({task_id},{operation},{subtask_number},{size}) finished, cost {time}ms. [PID,TID]
Field Meaning
task_id Unique identifier for the store task
operation Cache Store: DUMP (Device→Host) or LOAD (Host→Device); Posix Store: Cache2Backend (dump to storage) or Backend2Cache (load from storage)
subtask_number Number of subtasks in this operation
size Total data size transferred in bytes
cost Execution time in ms

To customize the log directory:

export UCM_LOG_PATH=my_log_dir

By default, logs are placed under the log directory relative to where the vLLM service was started.